The TASCO TA430ST-EXP is an explosion-proof refrigerant leak detector designed to detect HFC, HCFC, and hydrocarbon (HC) refrigerants like R32, R290, and R600a even in cold environments down to -20°C.
FEATURES:
- Equipped with a data logger function that can record the date, time, and gas concentration of gas detection for up to 256 points.
- Equipped with an LED light, allowing for accurate measurement even in dark places by making it easy to identify the measurement point.
- Improved shock resistance, IP67 equivalent protection rating, and protective cover to prevent dirt.
INCLUDES:
- 1 X TA430ST-EXP
- 1 X Instruction Manual
SPECIFICATIONS:
- Detection Principle: Hot-wire semiconductor type
- Target Gas: R600a (i-C4H10) (2.7g/year), R22 (4.1g/year), R32 (2.4g/year), R404A (4.6g/year), R407C (4.0g/year), R410A (3.4g/year), R134a (9.58g/year), R290 (propane) (2.1g/year), R1234yf (5.3g/year)
- R448A and R449A Sensitivity: Same sensitivity as R404A
- Concentration Display: LCD bar meter + scale
- Detection Method: Pump suction type
- Gas Alarm Display: Lamp flashing / Buzzer sounding / LED lighting
- Power Supply: 2 x AA alkaline batteries
- Continuous Usage Time: Approximately 13 hours (at room temperature, no alarms, and no lights)
- Operating Temperature Range: -20 to 55°COperating Humidity Range: 95% RH or less (no condensation)
- Explosion-Proof Structure: Intrinsically safe explosion-proof construction compliant
- Protection Class: IP67 equivalent (excluding gas inlet and outlet ports)
- External Dimensions with Protective Cover: W approx. 45 × H 145 × D 42 mm
- External Dimensions without Protective Cover: W approx. 41 × H 143 × D 38 mm (excluding protrusions)
- Weight with Protective Cover: Approximately 220gWeight without Protective Cover: Approximately 180g (excluding batteries)
- Alarm Sound/Operation Sound: ON/OFF switching
- Standard Accessories: Flexible probe, tapered nozzle, protective cover, 2 x AA alkaline batteries, hand strap, 5 x replacement waterproof filters, inspection gas